Columns and beams are the primary load-bearing skeleton of any RCC structure. When structural elements suffer from corrosion, low concrete grade, severe cracking or increased loading demands, structural strengthening is required. KR Foundation provides column and beam strengthening in Chennai, including RCC and steel jacketing methods.
What is jacketing?
Jacketing involves casting an additional structural sleeve around an existing column or beam to enlarge its cross-sectional area and load-carrying capacity:
- Reinforced Concrete (RC) Jacketing: New vertical reinforcement bars and lateral ties are installed around the existing column, anchored using chemical shear dowels, and cast with high-strength micro-concrete.
- Steel Jacketing: Steel angle collars and battens are clamped around the column, with gaps filled with non-shrink structural epoxy grout.
- Beam Jacketing: Bottom and side enlargement with stirrup anchoring to increase flexural and shear capacity.
- Section Restoration: Chipping out carbonated, delaminated concrete, anti-corrosion coating on steel, and restoring original geometry.
When might you need strengthening?
- Adding upper floors or converting room usage for heavy storage
- Aging structures showing concrete spalling, exposed rusting bars, and vertical load cracks
- Structural audit reveals concrete strength has degraded below safety limits
- Settlement or seismic distress requiring increased member ductility
- Retrofitting older buildings to comply with current IS safety standards
Our approach
- Condition survey: Visual inspection, NDT concrete testing, and corrosion mapping.
- Structural scheme & propping: Sizing the jacket and designing temporary heavy-duty propping to relieve member loads during work.
- Surface chipping & rebar treatment: Removing weak concrete, wire-brushing reinforcement, and applying zinc-rich primer.
- Anchorage & cage erection: Drilling chemical shear dowels and tying the new reinforcement cage.
- Shuttering & pouring: High-flow, self-compacting micro-concrete poured and compacted without voids.
- Curing & finishing: Strict wet curing followed by architectural plaster finishing.
Benefits and practical outcomes
- Restores and significantly upgrades structural safety margin
- Avoids the enormous cost, delay, and disruption of building demolition
- Engineered execution ensuring monolithic bond between old and new concrete
Frequently Asked Questions
What is the difference between jacketing and CFRP wrapping?
Jacketing enlarges member dimensions and adds significant concrete and steel cross-section. CFRP is very thin (millimeters) and adds strength without taking up room space.
Does column jacketing reduce usable floor space?
RC jacketing typically increases column dimensions by 75mm to 100mm on each jacketed face. Space impacts are planned with owners before commencement.
Can strengthening be performed while the building is occupied?
Yes, through phased execution and temporary propping. Work zones are safely cordoned off floor by floor.
How do engineers know which columns need jacketing?
Through visual distress mapping, UPV testing, rebound hammer tests, and computerized structural re-analysis against current dead and live loads.
Do I need structural drawings for jacketing?
Yes. Rebar sizes, tie spacings, dowel depths, and concrete grades must follow certified structural engineering drawings.